Conor D Barrett, Mb.Bch,Bao
Co-Author
This page shows the publications co-authored by Conor Barrett and Jeremy Ruskin.
Connection Strength
0.728
-
Ventricular Tachycardia Ablation-For Whom, When, and How? Card Electrophysiol Clin. 2009 Dec; 1(1):201-211.
Score: 0.105
-
Feasibility and safety of uninterrupted rivaroxaban for periprocedural anticoagulation in patients undergoing radiofrequency ablation for atrial fibrillation: results from a multicenter prospective registry. J Am Coll Cardiol. 2014 Mar 18; 63(10):982-8.
Score: 0.035
-
Esophageal temperature monitoring during AF ablation: multi-sensor or single-sensor probe? Response to letter to the editor. J Cardiovasc Electrophysiol. 2013 Dec; 24(12):E25.
Score: 0.035
-
Multi-sensor esophageal temperature probe used during radiofrequency ablation for atrial fibrillation is associated with increased intraluminal temperature detection and increased risk of esophageal injury compared to single-sensor probe. J Cardiovasc Electrophysiol. 2013 Sep; 24(9):958-64.
Score: 0.034
-
Comparison of electroanatomical mapping systems: accuracy in left atrial mapping. Pacing Clin Electrophysiol. 2013 May; 36(5):626-31.
Score: 0.033
-
Rapid acquisition of high-resolution electroanatomical maps using a novel multielectrode mapping system. J Interv Card Electrophysiol. 2013 Apr; 36(3):233-42.
Score: 0.033
-
Predictors of atrial fibrillation termination and clinical success of catheter ablation of persistent atrial fibrillation. Am J Cardiol. 2012 Aug 15; 110(4):545-51.
Score: 0.031
-
Unpredictable battery depletion of St Jude Atlas II and Atlas+ II HF implantable cardioverter-defibrillators. Heart Rhythm. 2012 May; 9(5):717-20.
Score: 0.030
-
Severity of esophageal injury predicts time to healing after radiofrequency catheter ablation for atrial fibrillation. Heart Rhythm. 2011 Dec; 8(12):1862-8.
Score: 0.030
-
Respiratory compensation improves the accuracy of electroanatomic mapping of the left atrium and pulmonary veins during atrial fibrillation ablation. J Interv Card Electrophysiol. 2011 Nov; 32(2):105-10.
Score: 0.029
-
Accuracy of left atrial anatomical maps acquired with a multielectrode catheter during catheter ablation for atrial fibrillation. J Interv Card Electrophysiol. 2011 Oct; 32(1):45-51.
Score: 0.029
-
Analysis of the left atrial appendage morphology by intracardiac echocardiography in patients with atrial fibrillation. J Interv Card Electrophysiol. 2011 Sep; 31(3):191-6.
Score: 0.029
-
Effectiveness of a strategy to reduce major vascular complications from catheter ablation of atrial fibrillation. J Interv Card Electrophysiol. 2011 Apr; 30(3):211-5.
Score: 0.029
-
Direct visualization of epicardial structures and ablation utilizing a visually guided laser balloon catheter: preliminary findings. J Cardiovasc Electrophysiol. 2011 Jul; 22(7):808-12.
Score: 0.029
-
Assessment of catheter tip contact force resulting in cardiac perforation in swine atria using force sensing technology. Circ Arrhythm Electrophysiol. 2011 Apr; 4(2):218-24.
Score: 0.029
-
Initial experience with a multielectrode catheter equipped with the single-axis sensor technology for high-density electroanatomical mapping in a swine model. J Cardiovasc Electrophysiol. 2010 Dec; 21(12):1403-7.
Score: 0.028
-
Incidence and electrophysiologic properties of dissociated pulmonary vein activity following pulmonary vein isolation during catheter ablation of atrial fibrillation. J Cardiovasc Electrophysiol. 2010 Dec; 21(12):1338-43.
Score: 0.028
-
Combined use of cryoballoon and focal open-irrigation radiofrequency ablation for treatment of persistent atrial fibrillation: results from a pilot study. Heart Rhythm. 2010 Apr; 7(4):452-8.
Score: 0.027
-
The relationship between electrogram cycle length and dominant frequency in patients with persistent atrial fibrillation. J Cardiovasc Electrophysiol. 2009 Dec; 20(12):1336-42.
Score: 0.026
-
Impact of tricuspid regurgitation and prior coronary bypass surgery on the geometry of the coronary sinus: a rotational coronary angiography study. J Cardiovasc Electrophysiol. 2010 Apr; 21(4):436-40.
Score: 0.026
-
Relevance of imaging structures adjacent to the left atrium during catheter ablation for atrial fibrillation. Heart Rhythm. 2010; 7(2):269-75.
Score: 0.026
-
Right atrial thrombus aspiration guided by intracardiac echocardiography during catheter ablation for atrial fibrillation. Circ Arrhythm Electrophysiol. 2009 Aug; 2(4):e18-20.
Score: 0.026
Connection Strength
The connection strength for co-authors is the sum of the scores for each of their shared publications.
Publication scores are based on many factors, including how long ago they were written and whether the person is a first or senior author.