Harvard Catalyst Profiles

Contact, publication, and social network information about Harvard faculty and fellows.

Bastien Pierre Guerin, Ph.D.

Co-Author

This page shows the publications co-authored by Bastien Guerin and Mathias Davids.
Connection Strength

2.441
  1. Fast three-dimensional inner volume excitations using parallel transmission and optimized k-space trajectories. Magn Reson Med. 2016 10; 76(4):1170-82.
    View in: PubMed
    Score: 0.657
  2. A Huygens' surface approach to rapid characterization of peripheral nerve stimulation. Magn Reson Med. 2021 Aug 24.
    View in: PubMed
    Score: 0.246
  3. Optimization of MRI Gradient Coils With Explicit Peripheral Nerve Stimulation Constraints. IEEE Trans Med Imaging. 2021 01; 40(1):129-142.
    View in: PubMed
    Score: 0.235
  4. Investigating cardiac stimulation limits of MRI gradient coils using electromagnetic and electrophysiological simulations in human and canine body models. Magn Reson Med. 2021 02; 85(2):1047-1061.
    View in: PubMed
    Score: 0.229
  5. Optimizing selective stimulation of peripheral nerves with arrays of coils or surface electrodes using a linear peripheral nerve stimulation metric. J Neural Eng. 2020 01 14; 17(1):016029.
    View in: PubMed
    Score: 0.220
  6. The 'virtual DBS population': five realistic computational models of deep brain stimulation patients for electromagnetic MR safety studies. Phys Med Biol. 2019 02 04; 64(3):035021.
    View in: PubMed
    Score: 0.206
  7. Sensitivity analysis of neurodynamic and electromagnetic simulation parameters for robust prediction of peripheral nerve stimulation. Phys Med Biol. 2018 12 19; 64(1):015005.
    View in: PubMed
    Score: 0.204
  8. Prediction of peripheral nerve stimulation thresholds of MRI gradient coils using coupled electromagnetic and neurodynamic simulations. Magn Reson Med. 2019 01; 81(1):686-701.
    View in: PubMed
    Score: 0.199
  9. Predicting Magnetostimulation Thresholds in the Peripheral Nervous System using Realistic Body Models. Sci Rep. 2017 07 13; 7(1):5316.
    View in: PubMed
    Score: 0.185
  10. A 31-channel integrated "AC/DC" B0 shim and radiofrequency receive array coil for improved 7T MRI. Magn Reson Med. 2021 Oct 10.
    View in: PubMed
    Score: 0.062
Connection Strength
The connection strength for co-authors is the sum of the scores for each of their shared publications.

Publication scores are based on many factors, including how long ago they were written and whether the person is a first or senior author.
Funded by the NIH National Center for Advancing Translational Sciences through its Clinical and Translational Science Awards Program, grant number UL1TR002541.