  1. Ex vivo stability loss of irradiated and melted ultra-high molecular weight polyethylene. J Bone Joint Surg Am. 2010 Dec 01; 92(17):2809-16.
    View in: PubMed
    Score: 0.467
  2. The stepwise introduction of innovation into orthopedic surgery: the next level of dilemmas. J Arthroplasty. 2011 Sep; 26(6):825-31.
    View in: PubMed
    Score: 0.462
  3. Progression of adverse local tissue reaction in ASR metal-on-metal hip arthroplasty: a longitudinal MARS-MRI study at mid- to long-term. Hip Int. 2021 May; 31(3):369-377.
    View in: PubMed
    Score: 0.219
  4. Current evidence from a worldwide, multicentre, follow-up study of the recalled Articular Surface Replacement Hip System. Hip Int. 2021 May; 31(3):378-387.
    View in: PubMed
    Score: 0.217
  5. Obesity is not associated with hip failure in patients with articular surface replacement of the hip. Hip Int. 2020 Jan; 30(1):78-86.
    View in: PubMed
    Score: 0.207
  6. What Is the Clinical Presentation of Adverse Local Tissue Reaction in Metal-on-metal Hip Arthroplasty? An MRI Study. Clin Orthop Relat Res. 2019 02; 477(2):353-360.
    View in: PubMed
    Score: 0.206
  7. Evaluation of in vivo wear of vitamin E-diffused highly crosslinked polyethylene at five years: a multicentre radiostereometric analysis study. Bone Joint J. 2018 12; 100-B(12):1592-1599.
    View in: PubMed
    Score: 0.203
  8. Response to Letter to the Editor on "Indications for MARS-MRI in Patients Treated With Articular Surface Replacement XL Total Hip Arthroplasty". J Arthroplasty. 2019 03; 34(3):606-607.
    View in: PubMed
    Score: 0.202
  9. Establishing thresholds for metal ion levels in patients with bilateral Articular Surface Replacement hip arthroplasty. Hip Int. 2019 Sep; 29(5):475-480.
    View in: PubMed
    Score: 0.198
  10. Periprosthetic acetabular radiolucency progression in mid-term follow-up of the articular surface replacement hip system. Arch Orthop Trauma Surg. 2018 Jul; 138(7):1021-1028.
    View in: PubMed
    Score: 0.196
  11. Ceramic bearings for total hip arthroplasty are associated with a reduced risk of revision for infection. Hip Int. 2018 May; 28(3):222-226.
    View in: PubMed
    Score: 0.195
  12. Indications for MARS-MRI in Patients Treated With Articular Surface Replacement XL Total Hip Arthroplasty. J Arthroplasty. 2018 09; 33(9):2906-2911.
    View in: PubMed
    Score: 0.195
  13. The Cobalt/Chromium Ratio Provides Similar Diagnostic Value to a Low Cobalt Threshold in Predicting Adverse Local Tissue Reactions in Patients With Metal-on-Metal Hip Arthroplasty. J Arthroplasty. 2018 09; 33(9):3020-3024.
    View in: PubMed
    Score: 0.194
  14. Indications for MARS-MRI in Patients Treated With Metal-on-Metal Hip Resurfacing Arthroplasty. J Arthroplasty. 2018 06; 33(6):1919-1925.
    View in: PubMed
    Score: 0.192
  15. Risk factors for mid-term revision surgery in patients with articular surface replacement total hip arthroplasty. Hip Int. 2018 Jan; 28(1):44-49.
    View in: PubMed
    Score: 0.191
  16. Inferior Radiographic and Functional Outcomes With Modular Stem in Metal-on-Metal Total Hip Arthroplasty. J Arthroplasty. 2018 02; 33(2):464-469.
    View in: PubMed
    Score: 0.187
  17. Mid-term changes in blood metal ion levels after Articular Surface Replacement arthroplasty of the hip. Bone Joint J. 2017 Apr; 99-B(4 Supple B):33-40.
    View in: PubMed
    Score: 0.181
  18. Scoring the Current Risk Stratification Guidelines in Follow-up Evaluation of Patients After Metal-on-Metal Hip Arthroplasty: A Proposal for a Metal-on-Metal Risk Score Supporting Clinical Decision-Making. J Bone Joint Surg Am. 2016 Nov 16; 98(22):1905-1912.
    View in: PubMed
    Score: 0.176
  19. Worse health-related quality of life and hip function in female patients with elevated chromium levels. Acta Orthop. 2016 Oct; 87(5):485-91.
    View in: PubMed
    Score: 0.173
  20. Are Females at Greater Risk for Revision Surgery After Hip Resurfacing Arthroplasty With the Articular Surface Replacement Prosthesis? Clin Orthop Relat Res. 2016 Oct; 474(10):2257-65.
    View in: PubMed
    Score: 0.170
  21. Medial Calcar Erosion Is Associated With Synovial Thickness in Patients With ASR XL Total Hip Arthroplasty. J Arthroplasty. 2016 11; 31(11):2588-2592.
    View in: PubMed
    Score: 0.169
  22. Reducing the distal profile of dual mobility liners can mitigate soft-tissue impingement and liner entrapment without affecting mechanical performance. J Orthop Res. 2016 05; 34(5):889-97.
    View in: PubMed
    Score: 0.164
  23. Early Lessons From a Worldwide, Multicenter, Followup Study of the Recalled Articular Surface Replacement Hip System. Clin Orthop Relat Res. 2016 Jan; 474(1):166-74.
    View in: PubMed
    Score: 0.162
  24. Cruciate Retaining Implant With Biomimetic Articular Surface to Reproduce Activity Dependent Kinematics of the Normal Knee. J Arthroplasty. 2015 Dec; 30(12):2149-53.e2.
    View in: PubMed
    Score: 0.160
  25. Regaining Native Knee Kinematics Following Joint Arthroplasty: A Novel Biomimetic Design with ACL and PCL Preservation. J Arthroplasty. 2015 Dec; 30(12):2143-8.
    View in: PubMed
    Score: 0.160
  26. The Symmetry of Adverse Local Tissue Reactions in Patients with Bilateral Simultaneous and Sequential ASR Hip Replacement. J Arthroplasty. 2015 Oct; 30(10):1794-8.
    View in: PubMed
    Score: 0.159
  27. In Vivo Oxidative Stability Changes of Highly Cross-Linked Polyethylene Bearings: An Ex Vivo Investigation. J Arthroplasty. 2015 Oct; 30(10):1828-34.
    View in: PubMed
    Score: 0.159
  28. Material Properties of a Highly Anteverted Vitamin E-Stabilized Polyethylene Liner After Sixteen Months In Vivo: A Case Report. JBJS Case Connect. 2014 Jul 09; 4(3):e57.
    View in: PubMed
    Score: 0.150
  29. In vivo biological response to vitamin E and vitamin-E-doped polyethylene. J Bone Joint Surg Am. 2010 Nov 17; 92(16):2672-81.
    View in: PubMed
    Score: 0.116
  30. Assessing the utility of deep neural networks in predicting postoperative surgical complications: a retrospective study. Lancet Digit Health. 2021 08; 3(8):e471-e485.
    View in: PubMed
    Score: 0.061
  31. Natural language processing with deep learning for medical adverse event detection from free-text medical narratives: A case study of detecting total hip replacement dislocation. Comput Biol Med. 2021 02; 129:104140.
    View in: PubMed
    Score: 0.058
  32. Infographic: Total hip arthroplasty component wear and stability. Bone Joint J. 2019 Jul; 101-B(7):758-759.
    View in: PubMed
    Score: 0.053
  33. Evaluation of vitamin E-diffused highly crosslinked polyethylene wear and porous titanium-coated shell stability: a seven-year randomized control trial using radiostereometric analysis. Bone Joint J. 2019 Jul; 101-B(7):760-767.
    View in: PubMed
    Score: 0.053
  34. Cadaver-Specific Models for Finite-Element Analysis of Iliopsoas Impingement in Dual-Mobility Hip Implants. J Arthroplasty. 2018 11; 33(11):3574-3580.
    View in: PubMed
    Score: 0.049
  35. A Fully Functional Drug-Eluting Joint Implant. Nat Biomed Eng. 2017; 1.
    View in: PubMed
    Score: 0.046
  36. ACL substitution may improve kinematics of PCL-retaining total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc. 2018 May; 26(5):1445-1454.
    View in: PubMed
    Score: 0.044
  37. Analysis of Dual Mobility Liner Rim Damage Using Retrieved Components and Cadaver Models. J Arthroplasty. 2016 07; 31(7):1595-602.
    View in: PubMed
    Score: 0.041
  38. Reverse Engineering Nature to Design Biomimetic Total Knee Implants. J Knee Surg. 2015 Oct; 28(5):363-9.