"Thermodilution" is a descriptor in the National Library of Medicine's controlled vocabulary thesaurus,
MeSH (Medical Subject Headings). Descriptors are arranged in a hierarchical structure,
which enables searching at various levels of specificity.
Measurement of blood flow based on induction at one point of the circulation of a known change in the intravascular heat content of flowing blood and detection of the resultant change in temperature at a point downstream.
Below are MeSH descriptors whose meaning is more general than "Thermodilution".
Below are MeSH descriptors whose meaning is more specific than "Thermodilution".
This graph shows the total number of publications written about "Thermodilution" by people in Harvard Catalyst Profiles by year, and whether "Thermodilution" was a major or minor topic of these publication.
To see the data from this visualization as text,
click here.
Year | Major Topic | Minor Topic | Total |
---|
1993 | 0 | 1 | 1 |
1996 | 0 | 1 | 1 |
1997 | 0 | 1 | 1 |
1998 | 1 | 2 | 3 |
1999 | 0 | 1 | 1 |
2000 | 0 | 1 | 1 |
2001 | 0 | 1 | 1 |
2004 | 1 | 1 | 2 |
2007 | 1 | 1 | 2 |
2008 | 1 | 1 | 2 |
2009 | 0 | 3 | 3 |
2010 | 1 | 0 | 1 |
2011 | 1 | 0 | 1 |
2012 | 2 | 0 | 2 |
2013 | 0 | 1 | 1 |
2016 | 1 | 1 | 2 |
2017 | 0 | 2 | 2 |
2018 | 0 | 1 | 1 |
2019 | 0 | 2 | 2 |
2020 | 1 | 0 | 1 |
2021 | 1 | 0 | 1 |
Below are the most recent publications written about "Thermodilution" by people in Profiles.
-
Pulse Wave Analysis to Estimate Cardiac Output: Comment. Anesthesiology. 2021 08 01; 135(2):370-371.
-
Prognostic significance of thermodilution-derived coronary flow capacity in patients with deferred revascularisation. EuroIntervention. 2021 Feb 19; 16(14):1195-1203.
-
Importance of Noninvasive Cardiac Output Measurement in Children: Feasibility or Applicability? J Cardiothorac Vasc Anesth. 2021 05; 35(5):1358-1359.
-
Assessment of Right Heart Function during Extracorporeal Therapy by Modified Thermodilution in a Porcine Model. Anesthesiology. 2020 10 01; 133(4):879-891.
-
Echo is a good, not perfect, measure of cardiac output in critically ill surgical patients. J Trauma Acute Care Surg. 2019 08; 87(2):379-385.
-
Reply to Li, J "The Fick principle remains accurate to calculate cardiac output under hyperoxia". Acta Anaesthesiol Scand. 2019 07; 63(6):828.
-
Diagnostic and Prognostic Efficacy of Coronary Flow Capacity Obtained Using Pressure-Temperature Sensor-Tipped Wire-Derived Physiological Indices. JACC Cardiovasc Interv. 2018 04 23; 11(8):728-737.
-
Cardiac Output Measurements Based on the Pulse Wave Transit Time and Thoracic Impedance Exhibit Limited Agreement With Thermodilution Method During Orthotopic Liver Transplantation. Anesth Analg. 2018 01; 126(1):85-92.
-
Thermodilution vs Estimated Fick Cardiac Output Measurement in Clinical Practice: An Analysis of Mortality From the Veterans Affairs Clinical Assessment, Reporting, and Tracking (VA CART) Program and Vanderbilt University. JAMA Cardiol. 2017 10 01; 2(10):1090-1099.
-
The response to Trendelenburg position is minimally affected by underlying hemodynamic conditions in patients with aortic stenosis. J Anesth. 2017 Oct; 31(5):692-702.